| HP part number |
ProCurve Switch 8108fl
(J8727A) |
ProCurve Switch 8116fl
(J8728A) |
| Included Accessories |
1 ProCurve Switch fl Redundant Management Module (J8731A) 1 ProCurve 8108fl Redundant Switch Fabric Module (J8729A) 1 ProCurve Switch fl Redundant Power Supply (J8732A) |
1 ProCurve Switch fl Redundant Management Module (J8731A) 1 ProCurve 8116fl Redundant Switch Fabric Module (J8730A) 2 ProCurve Switch fl Redundant Power Supply (J8732A) |
| Ports |
8 open module slots Supports a maximum of 80 auto-sensing 100/1000 ports, or a combination 16 10-GbE ports 80 mini-GBICs |
16 open module slots Supports a maximum of 160 auto-sensing 100/1000 ports, or a combination 32 10-GbE ports 160 mini-GBICs |
| Power Supplies |
1 x J8732A 2 |
2 x J8732A 2 |
| Physical Characteristics |
|
|
| Dimensions |
21.5(d) x 17.3(w) x 22.7(h) in. (54.61 x 43.94 x 57.66 cm)(13U height) |
21.5(d) x 17.3(w) x 34.8(h) in. (54.61 x 43.94 x 88.39 cm)(20U height) |
| Weight |
219.7 lb. (99.66 kg)1 8-slot chassis, 2 switch fabric modules, 2 mgmt. modules, 2 fan trays, 3 p/s, 8 int. modules, Fully loaded |
340 lb. (154.22 kg)1 16-slot chassis, 2 switch fabric modules, 2 mgmt. modules, 2 fan trays, 3 p/s, 16 int. modules, Fully loaded |
| Memory and Processor |
|
|
| Fabric |
PowerPC IBM405 @ 266 MHz, 16 MB flash, 16 MB SRAM, 256 MB SDRAM |
PowerPC IBM405 @ 266 MHz, 16 MB flash, 16 MB SRAM, 256 MB SDRAM |
| Interface Module |
PowerPC IBM405 @ 266 MHz, 16 MB flash, 256 MB SDRAM; packet buffer size: 128 MB RL-DRAM per module |
PowerPC IBM405 @ 266 MHz, 16 MB flash, 256 MB SDRAM; packet buffer size: 128 MB RL-DRAM per module |
| Management Module |
PowerPC MPC7410 @ 400 MHz, 16 MB flash, 512 MB compact flash, 1 GB SDRAM |
PowerPC MPC7410 @ 400 MHz, 16 MB flash, 512 MB compact flash, 1 GB SDRAM |
| Mounting |
|
|
|
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only. Requires 2 or more persons or lift-jack assistance.
|
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only. Requires 2 or more persons or lift-jack assistance.
|
| Performance |
|
|
| Latency |
< 25 µs (FIFO 64-byte packets) |
< 25 µs (FIFO 64-byte packets) |
| 1000 Mb |
< (FIFO) |
|
| 10 Gbps |
< (FIFO) |
|
| Throughput |
up to 119 million pps |
up to 238 million pps |
| Routing/Switching capacity |
160 Gbps |
320 Gbps |
| Routing table size |
100000 entries |
100000 entries |
| Environment |
|
|
| Operating temperature |
41ºF to 104ºF (5ºC to 40ºC) |
41ºF to 104ºF (5ºC to 40ºC) |
| Operating relative humidity |
15% to 80% @ 104ºF (40ºC) |
15% to 80% @ 104ºF (40ºC) |
| Non-operating/storage temperature |
-40ºF to 158ºF (-40ºC to 70ºC) |
-40ºF to 158ºF (-40ºC to 70ºC) |
| Non-operating/storage relative humidity |
0% to 90% @ 149ºF (65ºC), non-condensing |
0% to 90% @ 149ºF (65ºC), non-condensing |
| Altitude |
up to 15000 ft. (4.57 km) |
up to 15000 ft. (4.57 km) |
| Electrical Characteristics |
|
|
| Max heat dissipation |
5119 BTU/hr(5400.55 kJ/hr) |
10238 BTU/hr(10801.09 kJ/hr) |
| Voltage |
100-125 / 200-240 VAC |
100-125 / 200-240 VAC |
| Current |
15 / 7 A |
30 / 15 A |
| Power consumption |
1500 W |
3000 W |
| Frequency |
50 / 60 Hz |
50 / 60 Hz |
| Safety |
|
|
|
CSA 22.2 No. 60950
EN 60950/IEC 60950
UL 1950 3rd edition
UL 60950-1
CAN/CSA 22.2 No. 60950
CAN/CSA 22.2 No. 60950-1
EN60825
|
CSA 22.2 No. 60950
EN 60950/IEC 60950
UL 1950 3rd edition
UL 60950-1
CAN/CSA 22.2 No. 60950
CAN/CSA 22.2 No. 60950-1
EN60825 |