|
|
|
|
HP part number |
ProCurve Switch 5304xl
(J4850A) |
ProCurve Switch 5308xl-48G
(J8167A) |
ProCurve Switch 5304xl-32G
(J8166A) |
|
|
|
|
Included accessories |
|
|
|
|
|
3 ProCurve Switch xl 16-Port 10/100/1000 Module (J4907A) |
2 ProCurve Switch xl 16-Port 10/100/1000 Module (J4907A) |
Ports |
4 open module slotsSupports a maximum of 96 auto-sensing 10/100 ports or 64 auto-sensing 10/100/1000 ports |
5 open module slots42 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T)Media Type: IEEE Auto-MDIXDuplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only1 RS-232C DB-9 console port6 dual-personality portscan use either the 10/100/1000 Gigabit RJ-45 port for UTP cabling or the mini-GBIC port with mini-GBIC transceiversSupports a maximum of 192 auto-sensing 10/100 ports or 112 auto-sensing 10/100/1000 ports, or a combination |
2 open module slots28 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T)Media Type: IEEE Auto-MDIXDuplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only1 RS-232C DB-9 console port4 dual-personality portscan use either the 10/100/1000 Gigabit RJ-45 port for UTP cabling or the mini-GBIC port with mini-GBIC transceiversSupports a maximum of 96 auto-sensing 10/100 ports or 56 auto-sensing 10/100/1000 ports, or a combination |
Power supplies |
|
|
|
|
includes: 1 x J4839A
1 open power supply slots |
includes: 1 x J4839A
1 open power supply slots |
includes: 1 x J4839A
1 open power supply slots |
Physical characteristics |
|
|
|
Dimensions |
15.3(d) x 17.4(w) x 5.25(h) in. (38.86 x 44.2 x 13.34 cm) (3U height) |
15.3(d) x 17.4(w) x 8.75(h) in. (38.86 x 44.2 x 22.23 cm) (5U height) |
15.3(d) x 17.4(w) x 5.25(h) in. (38.86 x 44.2 x 13.34 cm) (3U height) |
Weight |
21.71 lb. (9.85 kg), Fully loaded |
30.55 lb. (13.86 kg), Fully loaded |
24.25 lb. (11.0 kg), Fully loaded |
Memory and processor |
|
|
|
Fabric |
Motorola PowerPC @ 200 MHz, 12 MB flash, 32 MB SDRAM; packet buffer size: 36 MB |
Motorola PowerPC @ 200 MHz, 12 MB flash, 32 MB SDRAM |
Motorola PowerPC @ 200 MHz, 12 MB flash, 32 MB SDRAM |
Module |
|
ARM9 @ 66 MHz, 128 KB flash, 128 KB SRAM, 18 MB RDRAM; packet buffer size: 36 MB |
ARM9 @ 66 MHz, 128 KB flash, 128 KB SRAM, 18 MB RDRAM; packet buffer size: 36 MB |
Mounting |
|
|
|
|
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only |
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only |
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only |
Performance |
|
|
|
Latency |
< 6 µs (FIFO) |
< 6 µs (FIFO) |
< 6 µs (FIFO) |
Throughput |
up to 24 million pps |
up to 48 million pps |
up to 24 million pps |
Switch fabric speed |
38.4 Gbps |
76.8 Gbps |
38.4 Gbps |
|
Gbps |
Gbps |
Gbps |
Routing table size |
10000 entries |
10000 entries |
10000 entries |
Environment |
|
|
|
Operating temperature |
32ºF to 104ºF (0ºC to 40ºC) |
32ºF to 104ºF (0ºC to 40ºC) |
32ºF to 104ºF (0ºC to 40ºC) |
Operating relative humidity |
15% to 95% @ 104ºF (40ºC), non-condensing |
15% to 95% @ 104ºF (40ºC), non-condensing |
15% to 95% @ 104ºF (40ºC), non-condensing |
Non-operating/Storage temperature |
-40ºF to 158ºF (-40ºC to 70ºC) |
-40ºF to 158ºF (-40ºC to 70ºC) |
-40ºF to 158ºF (-40ºC to 70ºC) |
Non-operating/Storage relative humidity |
15% to 95% @ 149ºF (65ºC), non-condensing |
15% to 95% @ 149ºF (65ºC), non-condensing |
15% to 95% @ 149ºF (65ºC), non-condensing |
Altitude |
up to 15000 ft. (4.6 km) |
up to 15000 ft. (4.6 km) |
up to 15000 ft. (4.6 km) |
Electrical characteristics |
|
|
|
Maximum heat dissipation |
2152 BTU/hr (2270 kJ/hr) |
2152 BTU/hr (2270 kJ/hr) |
2152 BTU/hr (2270 kJ/hr) |
Voltage |
100-127 / 200-240 VAC |
100-127 / 200-240 VAC |
100-127 / 200-240 VAC |
Current |
8.2 / 3.8 A |
8.2 / 3.8 A |
8.2 / 3.8 A |
Power consumption |
630 W |
630 W |
630 W |
Frequency |
50 / 60 Hz |
50 / 60 Hz |
50 / 60 Hz |
Safety |
|
|
|
|
cUL (CSA 950)
EN 60950/IEC 60950
NOM-019-SCFI-1994
UL 1950 3rd edition |
cUL (CSA 950)
EN 60950/IEC 60950
NOM-019-SCFI-1994
UL 1950 3rd edition |
cUL (CSA 950)
EN 60950/IEC 60950
NOM-019-SCFI-1994
UL 1950 3rd edition |