HP part number |
ProCurve Switch 3400cl-24G
(J4905A) |
ProCurve Switch 3400cl-48G
(J4906A) |
|
|
|
Ports |
1 open module slots 20 RJ-45 10/100/1000 ports
(IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-T, IEEE 802.3ab Type 1000Base-T) Supports a maximum of 2 10-GbE ports or 24 Gigabit ports. 1 RS-232C DB-9 console port 4 Dual Personality Ports
each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or an open mini-GBIC slot (for use with mini-GBIC transceivers) |
1 open module slots 44 RJ-45 10/100/1000 ports
(IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-T, IEEE 802.3ab Type 1000Base-T) Supports a maximum of 2 10-GbE ports or 48 Gigabit ports. 1 RS-232C DB-9 console port 4 Dual Personality Ports
each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or an open mini-GBIC slot (for use with mini-GBIC transceivers) |
Physical characteristics |
|
|
Dimensions: |
14.45 x 17.32 x 1.73 in.
(36.7 x 44 x 4.4 cm)
1U height |
16.93 x 17.32 x 1.73 in.
(43 x 44 x 4.4 cm)
1U height |
Weight: |
10.27 lb (4.66 kg) |
10.84 lb (4.92 kg) |
Memory and processor |
|
|
Processor type and speed: |
Motorola PowerPC MPC8245, 266 MHz |
Motorola PowerPC MPC8245, 266 MHz |
|
Dual Flash |
Dual Flash |
Packet buffer size: |
2 MB (1 MB per 12 ports) |
4 MB (1 MB per 12 ports) |
Flash capacity: |
16 MB |
16 MB |
SDRAM: |
128 MB |
128 MB |
Performance |
|
|
1000 MB: |
< 6 µs |
< 6 µs |
10 Gb: |
< 10 µs |
< 10 µs |
Throughput: |
up to 64 million pps |
up to 99.5 million pps |
Routing/switching capacity: |
88 Gbps |
136 Gbps |
Routing table size: |
64000 entries |
64000 entries |
Environment |
|
|
Operating temperature: |
32 °F to 104 °F (0 °C to 40 °C) |
32 °F to 104 °F (0 °C to 40 °C) |
Operating relative humidity: |
15 % to 95 % at 104 °F (40 °C), noncondensing |
15 % to 95 % at 104 °F (40 °C), noncondensing |
Non-operating/storage temperature: |
-40 °F to 158 °F (-40 °C to 70 °C) |
-40 °F to 158 °F (-40 °C to 70 °C) |
Non-operating/storage relative humidty: |
15 % to 95 % at 149 °F (65 °C), noncondensing |
15 % to 95 % at 149 °F (65 °C), noncondensing |
Altitude: |
up to 15000 ft (4.6 km) |
up to 15091 ft (4.6 km) |
Acoustic: |
DIN 45635T.19 per ISO 7779 53 dB@ <80°F (25°C) |
DIN 45635T.19 per ISO 7779 53 dB@ <80°F (25°C) |
Electrical characteristics |
|
|
Description: |
The switch automatically adjusts to any voltage between 100-127 and 200-240 volts and either 50 or 60 Hz |
The switch automatically adjusts to any voltage between 100-127 and 200-240 V and either 50 or 60 Hz |
Maximum heat dissipation: |
307 BTU/hr ( 323.89 kJ/hr ); including use of optional cl module with optics |
482 BTU/hr ( 508.51 kJ/hr ); including use of optional cl module with optics |
Voltage: |
100-127 VAC/200-240 VAC |
100-127 VAC/200-240 VAC |
Current: |
2.0 A /1.0 A |
3.0 A /1.5 A |
Power: |
90 W |
141 W |
Frequency: |
50/60 Hz |
50/60 Hz |
Notes: |
Power Consumption data is MAX value. Max BTUs includes use of optional cl Module with optics. |
Power Consumption data is MAX value. Max BTUs includes use of optional cl Module with optics. |
Mounting |
|
|
|
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only |
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only |
Safety |
|
|
|
CSA 22.2 No. 60950; EN 60950/IEC 60950; UL 60950 |
CSA 22.2 No. 60950; EN 60950/IEC 60950; UL 60950 |